BPZWL - SEALED LEAD BATTERY-CLOSED CYLINDRICAL

  • MSDS: BPZWL
  • Manufacturer: GATES ENERGY PRODUCTS
  • Product Name: SEALED LEAD BATTERY-CLOSED CYLINDRICAL
  • National Stock Number: 6140-01-311-1923
Product Identification

Product ID:SEALED LEAD BATTERY-CLOSED CYLINDRICAL
MSDS Date:03/01/1990
FSC:6140
NIIN:01-311-1923
MSDS Number: BPZWL

Responsible Party
GATES ENERGY PRODUCTS
617 N. RIDGEVIEW DR.
WARRENSBURG, MO 64093
US

Emergency Phone: 816-429-2253

Info Phone: 816-429-2253

Cage: 19209

Contractor
HAYNES ENTERPRISE
4134 BEAUMONT, TX 77705 US

Telephone: 409-842-5709

Cage: 1GF04

Ingredients

LEAD (SARA III) (GROUPED WITH LEAD OXIDE - 69%)

CAS: 7439-92-1

RTECS: OF7525000

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9293

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


LEAD MONOXIDE (LITHARGE) (GROUPED WITH LEAD - 69%)

CAS: 1317-36-8

RTECS: OG1750000

OSHA PEL 0.05 MG/M3

ACGIH TLV: 0.05 MG/M3


NON HAZARDOUS INGREDIENTS

Fraction By Weight: 100%

OSHA PEL NOT RELEVANT

ACGIH TLV: NOT RELEVANT


SULFURIC ACID (SARA III)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 21%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NOT REPORTED
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THIS ITEM IS NON HAZARDOUS AS
SUPPLIED, IN NORMAL SERVICE SITUATIONS.
Explanation of Carcinogenicity:NOT APPLICABLE.
Effects of Overexposure:SKIN/EYES:BURNS(ONLY IF BATTERY CASE BECOMES
DAMAGED AND LEAKS ACID).
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:COMPLETELY FLUSH WITH WATER.SKIN:COMPLETELY FLUSH WITH
WATER.

Fire Fighting

Extinguishing Media:MULTI-PURPOSE DRY CHEMICAL OR MULTI-PURPOSE CARBON
DIOXIDE.
Fire Fighting Procedures:THIS ITEM IS NON-FLAMMABLE.COOL EXTERIOR OF
BATTERY TO AVOID RUPTURE.HMIS SUGGESTS USING A SELF CONTAINED
BREATHING APPARATUS WHENEVER FIGHTING A CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:HYDROGEN GAS IS AN EXPLOSION HAZARD.ACIDS
MISTS AND VAPORS ARE TOXIC AND CORROSIVE.

Accidental Release

Spill Release Procedures:AVOID CONTACT WITH THE ACID.USE SODA ASH OR
LIME TO NEUTRALIZE.FLUSH WITH EXCESS WATER.
Neutralizing Agent:SODA ASH,LIME.

Handling

Handling and Storage Precautions:DO NOT PUNCTURE BATTERY CASE.USE ONLY
APPROVED CHARGING METHODS;VENTILATE AREA.STORE AWAY FROM HEAT AND
SOURCES OF IGNITION.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:NONE NEEDED IN NORMAL SERVICE.HMIS SUGGESTS
NIOSH RESPIRATOR FOR ACID FUMES IN CASE OF EMERGENCY.
Ventilation:NONE NEEDED IN NORMAL SERVICE.
Protective Gloves:NOT NEEDED.
Eye Protection:NOT NEEDED.
Other Protective Equipment:NONE.HMIS SUGGESTS HAVING AVAILABLE
PROTECTIVE CLOTHING,BOOTS,EYEWASH STATION,RESPIRATOR FOR EMERGENCY.
Work Hygienic Practices:USE PRUDENT SANITARY AND HYGENIC PRACTICES.
Supplemental Safety and Health
THIS ITEM IS CONSIDERED AN ARTICLE(REFERENCE:MFG).

Chemical Properties

HCC:N1
Solubility in Water:INSOLUBLE
Appearance and Odor:NOT REPORTED

Stability

Stability Indicator/Materials to Avoid:YES
NONE REPORTED.
Stability Condition to Avoid:AVOID SHORTING(ONLY USE APPROVED CHARGING
METHODS),HEAT AND SOURCES OF IGNITION.
Hazardous Decomposition Products:ACIDS MIST/VAPORS.

Disposal

Waste Disposal Methods:PLACE IN AN ACID-PROOF CONTAINER.DO NOT
INCINERATE.FOLLOW FEDERAL,STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.